Battery Systems
We source and deploy battery systems directly from manufacturers—built to de-risk projects and keep them moving to COD. See below to view a variety of our select Tier 1 battery partners we support.
Cabinets (40 kWh to 4 MWh)
Modular battery storage systems designed for flexibility across a wide range of smaller commercial and industrial applications, with scalable configurations based on project needs.
| System | Size | Inverter | Model # | Operating Voltage | Certifications | FEOC Compliance |
|---|---|---|---|---|---|---|
Sol-Ark
L3 Series
|
Size
61.44 kWh outdoor / 40.96 kWh indoor
|
Inverter
Sol-Ark
|
Model #
L3 HVR-60 / L3 HV-60 / L3 HVR-40 / L3 HV-40
|
Operating Voltage
614 VDC / 410 VDC
|
Certifications
UL1973, UL9540, UL9540A, UL1741
|
FEOC Compliance
—
|
Lion Energy
POWERsave Cabinet
|
Size
101 kWh – 187 kWh base
|
Inverter
Lion Energy (included)
|
Model #
N/A
|
Operating Voltage
480 VAC
|
Certifications
UL1741, UL9540, UL1973, UL9540A, CSIP (E-5000 & E-5036), CEC Listed, HECO SRD V2.0
|
FEOC Compliance
—
|
RCT Power
CESS 200
|
Size
233 kWh base
|
Inverter
RCT Power (included)
|
Model #
N/A
|
Operating Voltage
480 VAC
|
Certifications
UL1973, UL9540A, UL9540, NFPA 69, UL174, SunSpec compliant, California Rule 21, IEEE2030.5
|
FEOC Compliance
—
|
Discover Energy
AES
|
Size
106 kWh – 426 kWh
|
Inverter
Dynapower / Sol-Ark
|
Model #
See datasheet
|
Operating Voltage
332.8 – 1,331.2 VDC
|
Certifications
UL1973, UL9540A, UL9540
|
FEOC Compliance
—
|
RCT Power
CESS 1000
|
Size
466 kWh – 932 kWh
|
Inverter
RCT Power (included)
|
Model #
N/A
|
Operating Voltage
250 – 500 VAC
|
Certifications
UL1973, UL9540A, UL9540, NFPA 69, UL1741, SunSpec compliant, California Rule 21, IEEE2030.5, OpenADR
|
FEOC Compliance
—
|
CATL
EnerOne+
|
Size
407.34 kWh
|
Inverter
Dynapower / EPC Power
|
Model #
R08306P05L31
|
Operating Voltage
1,331.2 VDC
|
Certifications
UL1973, UL9540A, UL9540
|
FEOC Compliance
—
|
Risen / SYL
eFlex
|
Size
836 kWh
|
Inverter
Dynapower / EPC Power
|
Model #
SU836U418KM
|
Operating Voltage
1,331.2 VDC
|
Certifications
UL9540, UL9540A, UL1973, UL1741
|
FEOC Compliance
—
|
|
Risen / SYL
iCon
|
Size
261 kWh
|
Inverter
Risen
|
Model #
SU261E125LM
|
Operating Voltage
400 VAC
|
Certifications
UL9540, CEC Listed
|
FEOC Compliance
—
|
Generac
SBE Cabinet
|
Size
250 kWh – 1 MWh
|
Inverter
Included
|
Model #
SBE-Cabinet-125
|
Operating Voltage
480 VAC
|
Certifications
UL1642, UL1973, UL9540A, UL1741 SB, UL9540, NFPA 68
|
FEOC Compliance
✓ Compliant
|
Hithium
ESS Cabinet
|
Size
261 kWh
|
Inverter
Hithium
|
Model #
HiTHIUM LFP 314Ah
|
Operating Voltage
400 VAC
|
Certifications
TBD
|
FEOC Compliance
—
|
Ampace
UniC
|
Size
256 kWh
|
Inverter
Ampace
|
Model #
AG256-125
|
Operating Voltage
400 VAC
|
Certifications
TBD
|
FEOC Compliance
—
|
Ampace
UniC (HV)
|
Size
256 kWh
|
Inverter
Dynapower / EPC Power
|
Model #
TBD
|
Operating Voltage
1,120 – 1,440 VDC
|
Certifications
TBD
|
FEOC Compliance
—
|
Containers (2.25 MWh to 5+ MWh)
Larger battery storage systems built for higher-capacity applications and grid-level deployments, supports projects up to 100 MWh.
| System | Size | Inverter | Model # | Operating Voltage | Certifications | FEOC Compliance |
|---|---|---|---|---|---|---|
Tesla
Megapack 2 / 2XL
|
Size
2,595 kWh – 3,085 kWh
|
Inverter
Tesla
|
Model #
2XL: 1848844-XX-Y
|
Operating Voltage
480 VAC
|
Certifications
UL1973, UL9540, UL9540A, UL1741
|
FEOC Compliance
TBD
|
Risen / SYL
eTron
|
Size
5,015.96 kWh
|
Inverter
Risen / SYL
|
Model #
SU5016U2500KC
|
Operating Voltage
480 VAC
|
Certifications
UL9540, UL9540A, UL1973
|
FEOC Compliance
—
|
CATL
EnerX
|
Size
5,644.29 kWh
|
Inverter
Dynapower / EPC Power
|
Model #
C06530P25L01
|
Operating Voltage
1,331.2 VDC
|
Certifications
UL9540, UL9540A, UL1973
|
FEOC Compliance
—
|
CATL
EnerC+
|
Size
4,073.47 kWh
|
Inverter
Dynapower / EPC Power
|
Model #
C02306P05L01
|
Operating Voltage
1,331.2 VDC
|
Certifications
UL9540A, UL1973
|
FEOC Compliance
—
|
Sunwoda
Noah-X
|
Size
4,170 kWh
|
Inverter
EPC Power
|
Model #
NoahX-1500/4170
|
Operating Voltage
1,331.2 VDC
|
Certifications
UL9540A, UL1973, NFPA 68, NFPA 69, NFPA 855
|
FEOC Compliance
—
|
Lion Energy
POWERsave PS20
|
Size
1,032 kWh – 3,440 kWh
|
Inverter
Lion Energy
|
Model #
N/A
|
Operating Voltage
480 / 690 VAC
|
Certifications
UL1973, UL9540A, UL9540, UL1741
|
FEOC Compliance
—
|
Generac
SBE Block
|
Size
2,508 kWh – 5,016 kWh
|
Inverter
Generac
|
Model #
SBE-B-[kWh]-[kW]
|
Operating Voltage
600 – 800 VAC
|
Certifications
NFPA 69, NFPA 68, UL9540, UL9540A, UL1973, UL1642, UL1741, NFPA 855, IEEE 1547
|
FEOC Compliance
✓ Compliant
|
Generac
SBE 1000
|
Size
1,152 kWh – 1,728 kWh
|
Inverter
Generac
|
Model #
SBE-[kWh]-[kW]
|
Operating Voltage
480 VAC
|
Certifications
CBC, IBC 2021, NFPA 69, NFPA 68, UL1642, UL1973, UL9540A, UL1741 SB
|
FEOC Compliance
✓ Compliant
|
Hithium
ESS Container 5.016 MWh
|
Size
5,016 kWh
|
Inverter
TBD
|
Model #
TBD
|
Operating Voltage
1,331.2 VDC
|
Certifications
UL1973, UL9540A, NFPA 855
|
FEOC Compliance
—
|